Type Alias: G3000EspDefinition
G3000EspDefinition =
object
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:18
A definition that describes how to create a G3000 electronic stability and protection (ESP) system.
Properties
armAglThreshold
readonlyarmAglThreshold:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:20
The above ground height, in feet, at or above which ESP can become armed from a disarmed state.
armMaxPitchLimit?
readonlyoptionalarmMaxPitchLimit:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:38
The maximum pitch angle, in degrees, at which ESP can become armed. Positive angles represent downward pitch.
Defaults to 90.
armMinPitchLimit?
readonlyoptionalarmMinPitchLimit:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:32
The minimum pitch angle, in degrees, at which ESP can become armed. Positive angles represent downward pitch.
Defaults to -90.
armRollLimit?
readonlyoptionalarmRollLimit:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:41
The maximum roll angle magnitude, in degrees, at which ESP can become armed. Defaults to 90.
canArmWhenAglInvalid?
readonlyoptionalcanArmWhenAglInvalid:boolean
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:26
Whether ESP can become armed when AGL data is invalid. Defaults to false.
controlInputManagerOptions?
readonlyoptionalcontrolInputManagerOptions:Readonly<G3000EspControlInputManagerOptions>
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:104
Options with which to configure the control input manager. Ignored if omitControlInputManager is true.
disarmAglThreshold
readonlydisarmAglThreshold:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:23
The above ground height, in feet, below which ESP becomes disarmed from an armed state.
engagementTimeWindow?
readonlyoptionalengagementTimeWindow:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:92
The length of the window, in seconds, in which engagement time is tracked. Values less than or equal to zero will
cause engagement time to not be tracked. Defaults to 0.
isArmingInhibited?
readonlyoptionalisArmingInhibited:Accessible<boolean>
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:98
Whether arming is inhibited due to external factors. If not defined, then arming is never inhibited due to external factors.
moduleFactories
readonlymoduleFactories: readonly () =>EspModule[]
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:107
Factories used to create the modules to add to the ESP system.
omitControlInputManager?
readonlyoptionalomitControlInputManager:boolean
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:101
Whether to omit the control input manager. Defaults to false.
pitchAxisForceRate?
readonlyoptionalpitchAxisForceRate:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:61
The rate at which the system changes the force applied to the pitch control axis, in units of force per second.
Defaults to 0.1.
pitchAxisMaxForceDown?
readonlyoptionalpitchAxisMaxForceDown:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:55
The maximum force ESP is allowed to apply to the pitch control axis to move it in the pitch down direction. A
force of magnitude one is the amount of force required to deflect the control axis from the neutral position to
maximum deflection (on either side). Defaults to 1.
pitchAxisMaxForceUp?
readonlyoptionalpitchAxisMaxForceUp:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:48
The maximum force ESP is allowed to apply to the pitch control axis to move it in the pitch up direction. A force
of magnitude one is the amount of force required to deflect the control axis from the neutral position to maximum
deflection (on either side). Defaults to 1.
pitchAxisUnloadRate?
readonlyoptionalpitchAxisUnloadRate:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:67
The rate at which the system unloads force applied to the pitch control axis when it is not armed, in units of
force per second. Defaults to 1.
rollAxisForceRate?
readonlyoptionalrollAxisForceRate:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:80
The rate at which the system changes the force applied to the roll control axis, in units of force per second.
Defaults to 0.1.
rollAxisMaxForce?
readonlyoptionalrollAxisMaxForce:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:74
The maximum force ESP is allowed to apply to the roll control axis. A force of magnitude one is the amount of
force required to deflect the control axis from the neutral position to maximum deflection (on either side).
Defaults to 1.
rollAxisUnloadRate?
readonlyoptionalrollAxisUnloadRate:number
Defined in: src/workingtitle-instruments-g3000/html_ui/Shared/ESP/G3000EspDefinition.ts:86
The rate at which the system unloads force applied to the roll control axis when it is not armed, in units of
force per second. Defaults to 1.