Operations
In addition to running trident install and trident update fully to
completion, Trident allows breaking these commands into separate stage and
finalize operations.
Stage
Staging an update is a background task that involves streaming partition images
and applying the indicated OS and bootloader configuration. It generally takes
on the order of 1-5 minutes, but because the modifications are occurring on
the inactive A/B volume partitions, the workload can continue running while
the stage operation is in progress.
Finalize
Finalizing an update configures the next boot and triggers a reboot. Unlike the
stage operation, finalize will reboot the machine, which is a
workload-disruptive action.
-
For
trident install, this means that the UEFI BootOrder variable is configured to boot the newly installed OS on all subsequent reboots. -
For
trident update, this means that the UEFI BootNext variable is configured to boot the newly installed OS on the next reboot. On the next boot,trident commitwill validate the boot and update the UEFI BootOrder variable for all subsequent reboots.
To understand how to use these operations, see the Two-Step Installation and Update guide.